Parallel Circuit - Constant Watts
Electric Heating Cables

Type
RPC

Description

Our RPC Parallel Circuit Heating Tape is designed to be cut to length on site from a reel and to be site terminated to suit the pipelength required. The cable gives a constant watts per metre output no matter what length is selected.

The cable heating core is two Bus-Wire conductors covered with high dielectric insulation. Spirally wound resistance wire maintains circuit continuity by connecting short alternately spaced sections of exposed bus wire conductor. A high temperature soldered joint is made at each contact point.

Each cable is protected against abrasion and impact with an over extruded and/or braided jacket.

 

 

Specification
Conductors Nickel plated stranded
Cores Silicone Rubber
Heater Element NickelChrome 80/20
Outer Sheath Silicone Rubber
Temperature Max 200C
Watts per metre 8W/m
Max circuit length 250Mts @240 volts
100Mts @110 volts
Watts per metre 16 W/m
Max circuit length 140Mts @ 240 volts
75Mts @ 110 volts
rpcj.GIF (24069 bytes)
   

Data Sheet Ref.
RPC/01/94

Main Electric Heating Tape Page | RPA | RPG | RPC | RSR